F-4D fluoropolymer tubes
(TU 6-05-1937-82)

Applications:
- for transportation of any aggressive media (except for melted alkali metals) at medium pressures up to 0,4 MPa;
- for lining of reactors and rectifying stills of column type, shut-off accessory, pumps, containers for storage of reactive media;
- for manufacturing of sealing parts, contacting with aggressive media;
- for manufacturing of flow transmitters and inductive counters;
- for manufacturing of transmitters of flow meters and inductive counters;
- for manufacturing of hanging contact network insulators of electrical railway transport.
Operating temperatures: from -60°Ñ up to +230°Ñ (for a liner).
Properties of tubes from Ftoroplast-4D
| Properties | Values and standards |
|---|---|
| Phisical: | |
| Density, g/cm3 | 2,19-2,22 (GOST 15139-69) |
| Water absorption, % | 0,00 |
| Gas permeability, m3 m/m2 ñPà | 0,87•10-16 |
| Thermal: | |
| Melting point, °Ñ | 327 |
| Specific heat, kJ/Êkg | 1,04 |
| Heat conductivity index, W/Êm | 0,22 |
| Operating temperatures, °Ñ — max. — min. |
250 -60 |
| Linear extension, 1/°Ñ•10-5 | 8 – 25 |
| Mechanical: | |
| Tensile strength in transverse direction at 23°Ñ, ÌPà: — pipes NB from 20 up to 200 mm — pipes NB from 220 up to 600 mm |
22,5 (GOSÒ 11262-80) 20,6 |
| Relative elongation at break in radial direction at 23°Ñ, % | 350 |
Dimensions of pipes from F-4D
| NB | Wall thickness, mm | Maximal length of one tube, m | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1,5 | 1,7 | 2 | 2,5 | 3 | 3,5 | 4 | 4,5 | 5 | 6 | 6,5 | ||
| 20 | × | × | 3 | |||||||||
| 25 | × | × | 3 | |||||||||
| 30 | × | × | 3 | |||||||||
| 40 | × | × | 3 | |||||||||
| 50 | × | × | 3 | |||||||||
| 65 | × | × | 3 | |||||||||
| 75 | × | × | 3 | |||||||||
| 100 | × | × | 3 | |||||||||
| 115 | × | × | 3 | |||||||||
| 125 | × | 3 | ||||||||||
| 150 | × | × | 3 | |||||||||
| 175 | × | × | 3 | |||||||||
| 200 | × | × | 3 | |||||||||
| 220 | × | × | 3 | |||||||||
| 250 | × | × | 3 | |||||||||
| 300 | × | × | 3 | |||||||||
| 400 | × | × | 3 | |||||||||
| 500 | × | × | 3 | |||||||||
| 600 | × | × | 3 | |||||||||
× – most used dimensions of tubes
Notice:
The pipes with NB up to 150 mm can be applied as pipelines, more than 150 mm, generally, as liners for metal pipes.
Hygienic certificate 78.01.06.224.Ï.005503.07.01 from 13.07.2001.